trial summary · NCT07372027
Single-Needle Distal Return for Long-Term Arteriovenous Fistula Care
A Prospective Study on the Efficacy and Cost-Effectiveness of Modified Single-Needle Distal Return Cannulation for Long-Term Arteriovenous Fistula Care in Maintenance Hemodialysis Patients
Trial record from the TrialBase DB dataset, status RECRUITING, condition Hemodialysis Access, sponsored by Suzhou Municipal Hospital of Anhui Province. Facts below are exported values from the current release, not inferred or edited prose.
Summary
The brief summary is the registry's published description, capped for length. Field definitions, types, and provenance rules are in the data dictionary.
Background: For millions of people worldwide with kidney failure, a well-functioning vascular access, like an arteriovenous fistula (AVF), is essential for life-sustaining hemodialysis. However, the standard method requires puncturing the same AVF with two needles three times a week, which over time can damage the vessel, leading to scarring, narrowing, and frequent failures. These complications often require repeated surgical or minimally invasive procedures (reinterventions), causing significant pain, high medical costs, and exhaustion of the patient's limited blood vessels. New Approach: This study will evaluate a modified puncture technique called the Single-Needle Distal Return (SNDR) strategy for long-term AVF care. Instead of using two needles in the AVF, only one needle is placed in the AVF to draw blood. The cleaned blood is then returned to the body through a second needle placed in a superficial vein in the foot or lower leg. This approach aims to reduce trauma to the critical AVF. Study Plan: This is a clinical study conducted at the Blood Purification Center of Anhui Medical University Affiliated Suzhou Hospital. We plan to enroll approximately 50 adult hemodialysis patients who use an AVF and are willing to try the SNDR technique. For comparison, we will also observe data from a similar number of patients receiving standard two-needle AVF care during the same period. The study will last about three years. We will closely monitor patients using the SNDR technique to assess: Effectiveness: Whether dialysis remains adequate (measured by Kt/V). Safety: Rates of …
Source record: https://clinicaltrials.gov/study/NCT07372027
Facts
| registry id | NCT07372027 |
|---|---|
| primary registry | clinicaltrials-gov |
| recruitment status | RECRUITING |
| phase | not reported |
| study type | INTERVENTIONAL |
| lead condition | Hemodialysis Access |
| sponsor | Suzhou Municipal Hospital of Anhui Province |
| sponsor class | OTHER |
| enrollment | 100 |
| start date | 2026-12-15 |
| primary completion | 2026-12-20 |
| completion | 2026-12-31 |
| results posted | not reported |
Conditions
- Hemodialysis Access
- Arteriovenous Fistula
- Arteriovenous Fistula Cannulation
- Vascular Access
- Vascular Access Complication
Interventions
- Single-Needle Distal Return (SNDR) Cannulation
- Standard Two-Needle AVF Cannulation
Countries
- China
Intervention types: PROCEDURE
Work with this record
- Field definitions
Types, scope, and provenance rules for every exported field.
- REST API
Query the same gate-backed records programmatically.
- Evaluation sample
Download a bounded slice before buying.
- $29 API Pass
Seven days of REST and MCP access; credited toward the licence.